Between the damper and the flue liner of a masonry fireplace sits a sloped, funnel-shaped space most homeowners never see. Its shape and surface have a big effect on how the fireplace drafts.

By the Chimney Orlando team 4 min read

Technician using a flashlight to inspect the inside of a brick masonry firebox

Where the smoke chamber is

In a masonry fireplace, smoke rises from the firebox through the throat and damper, then enters the smoke chamber: a space whose walls lean inward to narrow the wide fireplace opening down to the size of the flue. Behind the damper is a flat ledge, the smoke shelf, which catches rain and debris coming down the flue. Factory-built fireplaces don’t have a masonry smoke chamber; the transition is part of the metal unit.

Technician brushing a stone fireplace flue from the hearth beside a soot vacuum, floor covered with a drop cloth
Masonry chimney and fireplace, cutaway

Masonry chimney and fireplace, cutaway

  1. 1Chimney cap. Metal lid with mesh sides over the flue opening. Keeps rain, debris and animals out.
  2. 2Crown. The concrete or mortar top of the masonry, sloped to shed water away from the flue.
  3. 3Flue liner. Clay tile or metal lining that carries smoke up and protects the masonry from heat.
  4. 4Flashing. Metal that seals the joint between the chimney and the roof.
  5. 5Brick & mortar. The chimney structure. Mortar joints and brick faces absorb water when they wear.
  6. 6Smoke chamber. The sloped transition that funnels smoke from the firebox into the flue.
  7. 7Damper. Metal plate at the throat (or a sealing lid on top) that closes the flue when not in use.
  8. 8Firebox. Where the fire burns. Firebrick laid in heat-resistant mortar.
  9. 9Hearth. Non-combustible floor extension in front of the fireplace opening.
The smoke chamber narrows the opening above the damper down to the flue

Why the surface matters

Many smoke chambers were built by stepping (corbeling) courses of brick inward, leaving a staircase of ledges. Those steps create turbulence that slows smoke, catches creosote and can push smoke back out into the room. The Florida residential code requires the inside of the smoke chamber to be smooth, with its walls sloped within set limits (Florida Building Code, Residential, Chapter 10).

Airflow

Stepped (corbeled) chamber
Turbulent; smoke can roll back
Smooth (parged) chamber
Smoother flow into the flue

Creosote

Stepped (corbeled) chamber
Collects on every ledge
Smooth (parged) chamber
Less surface for buildup; easier to clean

Heat protection

Stepped (corbeled) chamber
Mortar joints can open, exposing gaps
Smooth (parged) chamber
Continuous insulating layer when properly applied

What parging is

Parging is applying a heat-rated refractory mortar or a proprietary smoke chamber coating over the chamber walls to make them smooth and seal cracks and open joints. It is done after the chamber is cleaned, and it is commonly recommended when an inspection finds a stepped chamber, open joints or gaps.

Signs of a smoke chamber problem

  • Smoke spills into the room even with the damper fully open and a warm flue. See a fireplace smoking into the room.
  • Heavy creosote above the damper that returns quickly after cleaning.
  • Mortar pieces or crumbling material on the smoke shelf or damper.
  • An inspection report noting open joints, gaps or corbeled brick.

How it’s inspected

The smoke chamber is hard to see from the firebox, even with a flashlight. It is usually viewed with a strong light and a mirror after cleaning, or during a full flue inspection. It is part of the flue evaluation in a Level 2 inspection, and it is cleaned during a routine chimney sweep. Parging and chamber repairs are covered under smoke chamber repair.

Smoking and heavy deposits are the two symptoms that most often lead back here; a fireplace smoking into the room and creosote buildup cover the other causes to rule out. Where the chamber sits relative to the damper and flue is shown in parts of a chimney. For how a masonry fireplace problem is handled locally, see fireplace repair in Winter Park.

References (1)

← All guides

Keep reading

Inspection

Level 1 vs Level 2 Chimney Inspection: Which Do You Need?

The three chimney inspection levels in NFPA 211 explained: what a Level 1 covers, the specific events that call for a Level 2, what a full-length flue scan looks for, and when a Level 3 is justified.

9 min readRead guide

FAQ

Questions readers ask

Straight answers. If yours isn’t here, send it with an estimate request and we’ll answer it directly.

Is a rough smoke chamber dangerous?

A stepped chamber by itself isn’t necessarily dangerous, but open joints and gaps can let heat reach combustible framing, and the ledges hold creosote. If an inspection finds gaps, have them repaired before using the fireplace.

Can smoke chamber problems cause a fireplace to smoke?

Yes. A chamber that is too steep, too shallow or stepped can disturb the flow of smoke into the flue. It is one of the causes considered after the damper, flue and house pressure have been ruled out.

Is there a smoke chamber in a prefab fireplace?

Not a masonry one. The metal unit has its own built-in transition to the flue, and it is inspected as part of the listed system.

Request service

Want a professional opinion on your system?

Share what you have and what you’re seeing. We’ll tell you what an inspection or service would cover.